The following chart shows the IPC-A-600F (or its supporting document
IPC-6012) inspection item and its call-outs. To the right shows how
we have elected to inspect for those items *.
| Characteristic |
IPC-600F
Guideline * |
PCBpro
Inspections |
|
Board
edges |
- Haloing and nicks maximum .100" or 50% of distance to
nearest conductor, whichever is less.
- No metal burrs; must be clean cut.
|
|
| Bow
and twist |
- General 1.5% max.
- SMT boards 0.75%. max.
|
|
|
Conductor
thickness |
- Table 3-9 (external)
- Table 3-8 (internal)
|
- One coupon per multilayer job micro sectioned
- Sample of panels PTH copper thickness after copper plating
(surface plating inferred from PTH plating)
|
| Copper
plating thickness, minimum in holes |
- Class 2, avg. .0008" , thin spots .0007"
- Class 3, avg. .001", thin spots .0008" (Table 3-2)
|
- Sample of panels PTH copper thickness after copper plating
|
|
Copper
plating voids |
- Class 2 - One Cu void allowed per hole in not more than 5%
of the holes.
- Class 3 - No Cu voids allowed.
- Shall not exceed 5% of hole length or 90° of circumference
(Table 3-3)
|
- 100% visual inspection after etching·
- One coupon per multilayer job micro sectioned
|
| Delamination/blisters |
- Evaluated in accordance with IPC-A-600
- Class 1 now same as Class 2, 3 (2.3.3)
- Evidence of delamination in micro section now refers to 2.3.3
instead of being automatically nonconforming (3.1.4)
|
- Post-HAL and Final inspection
|
|
Dewetting |
- Ground planes and traces: allowed
- Solder connection areas: max. 5% (Class 2, 3)
|
|
| Finish
plating voids |
- Class 2 - Three solder voids allowed per hole in not more
than 5% of the holes.
- Class 3 - One solder void per hole in not more than 5% of
the holes.
- Shall not exceed 5% of hole length or 90° of circumference
(Table 3-3)
|
|
|
Foreign
inclusions |
- Evaluated in accordance with IPC-A-600, except no maximum
dimension specified (3.3.2.1)
|
- In-process inspection (after etching, before mask)
|
| Gold
thickness |
- Class 2 - min. 30µ"· Class 3 - min. 50µ"·
Solderable gold - 30µ" maximum.
|
- Beta-backscatter measurement on sample after gold plating
|
|
Hole
location |
- As specified on procurement document.
|
- Not specifically checked, unless critical dimensions are noted
on the master drawing; controlled by PM on drill machine
|
| Hole
sizes |
- ±.004" for plated through holes, ±.003
for non-plated through holes, +.003 / - hole size for vias,
unless otherwise specified by customer
|
- Sample at Post-HAL inspection
|
| Mask
coverage |
|
|
|
Mask
cure & adhesion |
- No tackiness
- Blisters/delamination: 2 per side, max. .010 in, does not
reduce spacing by more than 25%
- Soda-strawing is now defined as applying to DFSM only (2.9.9)
|
|
| Mask
in holes |
- Allowed only in holes in which are not to be soldered.
|
|
|
Mask
registration |
|
|
| Mask
thickness |
- Visual coverage; no thickness requirement
|
- Not checked unless specifically required by drawing
|
|
Mask
touch-up |
- Touch-up material specified (IPC-A-600F 2.9.1)
|
|
| Measles/crazing |
- Evaluated in accordance with IPC-A-600
- Measles acceptable for all except high voltage applications
[not defined] (2.3.1)
- Crazing spec. now same as delamination except 50% of distance
between conductors may be spanned; also now shows pictures of
crazing (2.3.2)
|
- In-process inspection (after etch, before mask)
|
|
Min.
ann. ring NPTH |
- Class 2: No breakout allowed.
- Class 3: annular ring not less than .006, isolated 20% reductions
allowed (Table 3-5)
|
|
| Min.
ann. ring-internal |
- Class 2: 90° breakout allowed
- Class 3: .001 minimum annular ring (Table 3-5)
|
- Process control using micro sections, design check at front
end to ensure design is within capability
|
|
Min.
external ann. ring - PTH |
- Class 2: 90° breakout allowed except at junction of pad
and trace, where .002" minimum is allowed.
- Class 3: .002 minimum annular ring, except on vias (90°
breakout allowed).
|
- In-process inspection (after etch, before mask)
|
| Nomenclature
(silkscreen) |
- Refers to IPC-A-600 for legibility requirements Marking ink
on surface mount lands no longer nonconforming (IPC-A-600F 2.8.3)
|
|
|
Nonwetting |
|
|
| Pink
ring |
|
- In-process inspection (after etch, before mask)
|
|
Pits
and voids in base material |
- Acceptable if no larger than 0.8 mm [.03 in] and no more than
5% of board area
|
- In-process inspection (after etch, before mask)
|
| Plating
adhesion |
- Tape test required (slivers coming off with tape is not cause
for rejection)
|
- In-process inspection (after etch, before mask)
|
|
Plating
cracks |
- See Table 3-7 (basically none allowed)
|
- In-process inspection (after etch, before mask); One coupon
per multilayer job micro sectioned
|
| Resin
fill of blind/buried vias |
- Buried vias shall be at least 60% filled with resin (3.3.14)
|
- One coupon per multilayer job micro sectioned
|
|
Routing
tolerances |
- As specified on procurement document.
|
- Final inspection; sample checked per customer drawing or default
to ±.010
|
| Spacing
reduction |
- When not specified on the customer's documentation, 30% allowed
for class 2; 20% allowed for class 3.
|
- In-process inspection (after etch, before mask)
|
|
Tenting
(via holes) |
|
- Post-HAL inspection (when required)
|
| Tin/lead,
solder coat |
- Unfused tin-lead: min. .0003"
- Fused or HAL: coverage and solderable.
- Sidewalls do not have to be covered.
|
- Post-HAL inspection; solderability process control on multilayer
coupons
|
|
Trace
width |
- Class 2, 3: When not specified on the customer's documentation,
20% max. line loss, additional 20% for isolated defects
|
- In-process inspection (after etch, before mask)
|
| Weave
exposure and exposed/disrupted fibers |
- Acceptable for Class 1, 2, 3 as long as minimum conductor
spacing is met.
|
- In-process inspection (after etch, before mask)
|
|
Weave
texture |
|
|
* We seek to use the standard’s classification and defect determinations
to maintain a “Class II” quality level. Other aspects in
the IPC-6012 have been deviated from in an effort to keep our internal
costs down. We have elected instead to use our own system to maintain
quality. Our quality program, sampling plans, coupon use, record keeping,
and use of outside labs is different than the IPC-6012.