In an effort to insure quality for our Customers, PCBpro has adopted an inspection program using the IPC-600F as its guide. The IPC-600F, which is the pictorial guide for the IPC-6012, is an industry standard for classification of the Printed Circuit Board quality level.

The following chart shows the IPC-A-600F (or its supporting document IPC-6012) inspection item and its call-outs. To the right shows how we have elected to inspect for those items *.

IPC (formerly Institute of Interconnecting and Packaging Electronic Circuits) produces the IPC-A-600F pictorial guide.

Characteristic
IPC-600F Guideline *
PCBpro Inspections
Board edges
  • Haloing and nicks maximum .100" or 50% of distance to nearest conductor, whichever is less.
  • No metal burrs; must be clean cut.
  • Final inspection
Bow and twist
  • General 1.5% max.
  • SMT boards 0.75%. max.
  • Final inspection
Conductor thickness
  • Table 3-9 (external)
  • Table 3-8 (internal)
  • One coupon per multilayer job micro sectioned
  • Sample of panels PTH copper thickness after copper plating (surface plating inferred from PTH plating)
Copper plating thickness, minimum in holes
  • Class 2, avg. .0008" , thin spots .0007"
  • Class 3, avg. .001", thin spots .0008" (Table 3-2)
  • Sample of panels PTH copper thickness after copper plating
Copper plating voids
  • Class 2 - One Cu void allowed per hole in not more than 5% of the holes.
  • Class 3 - No Cu voids allowed.
  • Shall not exceed 5% of hole length or 90° of circumference (Table 3-3)
  • 100% visual inspection after etching·
  • One coupon per multilayer job micro sectioned
Delamination/blisters
  • Evaluated in accordance with IPC-A-600
  • Class 1 now same as Class 2, 3 (2.3.3)
  • Evidence of delamination in micro section now refers to 2.3.3 instead of being automatically nonconforming (3.1.4)
  • Post-HAL and Final inspection
Dewetting
  • Ground planes and traces: allowed
  • Solder connection areas: max. 5% (Class 2, 3)
  • Post-HAL inspection
Finish plating voids
  • Class 2 - Three solder voids allowed per hole in not more than 5% of the holes.
  • Class 3 - One solder void per hole in not more than 5% of the holes.
  • Shall not exceed 5% of hole length or 90° of circumference (Table 3-3)
  • Post-HAL inspection
Foreign inclusions
  • Evaluated in accordance with IPC-A-600, except no maximum dimension specified (3.3.2.1)
  • In-process inspection (after etching, before mask)
Gold thickness
  • Class 2 - min. 30µ"· Class 3 - min. 50µ"· Solderable gold - 30µ" maximum.
  • Beta-backscatter measurement on sample after gold plating
Hole location
  • As specified on procurement document.
  • Not specifically checked, unless critical dimensions are noted on the master drawing; controlled by PM on drill machine
Hole sizes
  • ±.004" for plated through holes, ±.003 for non-plated through holes, +.003 / - hole size for vias, unless otherwise specified by customer
  • Sample at Post-HAL inspection
Mask coverage
  • See 3.8.1
  • Post-HAL inspection
Mask cure & adhesion
  • No tackiness
  • Blisters/delamination: 2 per side, max. .010 in, does not reduce spacing by more than 25%
  • Soda-strawing is now defined as applying to DFSM only (2.9.9)
  • Post-HAL inspection
Mask in holes
  • Allowed only in holes in which are not to be soldered.
  • Post-HAL inspection
Mask registration
 
  • Post-HAL inspection
Mask thickness
  • Visual coverage; no thickness requirement
  • Not checked unless specifically required by drawing
Mask touch-up
  • Touch-up material specified (IPC-A-600F 2.9.1)
  • Final inspection
Measles/crazing
  • Evaluated in accordance with IPC-A-600
  • Measles acceptable for all except high voltage applications [not defined] (2.3.1)
  • Crazing spec. now same as delamination except 50% of distance between conductors may be spanned; also now shows pictures of crazing (2.3.2)
  • In-process inspection (after etch, before mask)
Min. ann. ring NPTH
  • Class 2: No breakout allowed.
  • Class 3: annular ring not less than .006, isolated 20% reductions allowed (Table 3-5)
  • Final inspection
Min. ann. ring-internal
  • Class 2: 90° breakout allowed
  • Class 3: .001 minimum annular ring (Table 3-5)
  • Process control using micro sections, design check at front end to ensure design is within capability
Min. external ann. ring - PTH
  • Class 2: 90° breakout allowed except at junction of pad and trace, where .002" minimum is allowed.
  • Class 3: .002 minimum annular ring, except on vias (90° breakout allowed).
  • In-process inspection (after etch, before mask)
Nomenclature (silkscreen)
  • Refers to IPC-A-600 for legibility requirements Marking ink on surface mount lands no longer nonconforming (IPC-A-600F 2.8.3)
  • Final inspection
Nonwetting
  • None allowed
  • Post-HAL inspection
Pink ring
  • Acceptable (3.3.2.6)
  • In-process inspection (after etch, before mask)
Pits and voids in base material
  • Acceptable if no larger than 0.8 mm [.03 in] and no more than 5% of board area
  • In-process inspection (after etch, before mask)
Plating adhesion
  • Tape test required (slivers coming off with tape is not cause for rejection)
  • In-process inspection (after etch, before mask)
Plating cracks
  • See Table 3-7 (basically none allowed)
  • In-process inspection (after etch, before mask); One coupon per multilayer job micro sectioned
Resin fill of blind/buried vias
  • Buried vias shall be at least 60% filled with resin (3.3.14)
  • One coupon per multilayer job micro sectioned
Routing tolerances
  • As specified on procurement document.
  • Final inspection; sample checked per customer drawing or default to ±.010
Spacing reduction
  • When not specified on the customer's documentation, 30% allowed for class 2; 20% allowed for class 3.
  • In-process inspection (after etch, before mask)
Tenting (via holes)
 
  • Post-HAL inspection (when required)
Tin/lead, solder coat
  • Unfused tin-lead: min. .0003"
  • Fused or HAL: coverage and solderable.
  • Sidewalls do not have to be covered.
  • Post-HAL inspection; solderability process control on multilayer coupons
Trace width
  • Class 2, 3: When not specified on the customer's documentation, 20% max. line loss, additional 20% for isolated defects
  • In-process inspection (after etch, before mask)
Weave exposure and exposed/disrupted fibers
  • Acceptable for Class 1, 2, 3 as long as minimum conductor spacing is met.
  • In-process inspection (after etch, before mask)
Weave texture
  • Not addressed
  • N/A

* We seek to use the standard’s classification and defect determinations to maintain a “Class II” quality level. Other aspects in the IPC-6012 have been deviated from in an effort to keep our internal costs down. We have elected instead to use our own system to maintain quality. Our quality program, sampling plans, coupon use, record keeping, and use of outside labs is different than the IPC-6012.

Back to top

Copyright 2007 PCBpro-Sunstone Circuits. All Rights Reserved.  


Printed circuit board links for your reference:
PCB quote links: pcb quote | pcb help | circuit board tutorial | pcb site map | pcb request for quote
Circuit board resource pcb links: pcb design tips | pcb glossary | circuit board manufacturing capabilities | pcb library
PCBpro company links: contact a pcb specialist | about pcb pro | pcb testimonials | privacy & security